{"product_id":"square-d-powerpact-b-bjl16020-20a-1p-600y-347vac-25ka-unit-mount-thermal-magnetic-circuit-breaker","title":"Square D PowerPacT B, BJL16020, 20A, 1P, 600Y\/347VAC, 25kA, Unit Mount, Thermal Magnetic, Circuit Breaker","description":"\u003ch4 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eSquare D BJL16020: 20 Amp, 1-Pole, PowerPacT B-Frame Molded Case Circuit Breaker, 600Y\/347VAC, 25kA, Unit Mount, Thermal Magnetic, 80%, UL Listed.\u003c\/h4\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Square D\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eProduct Range:\u003c\/strong\u003e PowerPacT B-Frame (for unit mount back pan and DIN rail applications)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 3606481193896\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e BJL16020\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eBreaker Type:\u003c\/strong\u003e Thermal Magnetic Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eTrip Unit:\u003c\/strong\u003e TM-D — Thermal Magnetic\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eTrip Functions:\u003c\/strong\u003e LI — Long-Time and Instantaneous\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 20 Amps\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eContinuous Current Rating:\u003c\/strong\u003e 80%\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 1-Pole\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 600Y\/347 Volts AC\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eInterrupt Rating:\u003c\/strong\u003e 25 kAIC @ 600Y\/347VAC; 65 kAIC @ 480Y\/277VAC; 100 kAIC @ 240VAC; 100 kAIC @ 208Y\/120VAC; 50 kAIC @ 125V DC\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eBreaking Capacity Code:\u003c\/strong\u003e J\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eFrame Size:\u003c\/strong\u003e B-Frame, 125A\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eMounting Mode:\u003c\/strong\u003e Unit mount — back pan (by screws) or DIN rail (35mm symmetrical)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eConnections \/ Terminals:\u003c\/strong\u003e EverLink lugs, line and load\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eWire Size:\u003c\/strong\u003e #14–3\/0 AWG Cu\/Al (rigid or stranded); #6–2\/0 AWG Cu\/Al (fine stranded)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 44.3 lb-in (#14–4 AWG); 79.7 lb-in (#3–3\/0 AWG)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Height: 5.4 in; Width: 1.06 in; Depth: 3.1 in\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.12 lbs\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e UL 489, CSA C22.2 No. 5, NEMA AB1, IEC\/EN 60947-2, NOM, NMX J-266, CCC, EAC, CE Marked, HACR Rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThis Square D BJL16020 PowerPacT B thermal magnetic molded case circuit breaker delivers dependable 20 Amp, 1-Pole protection for 600Y\/347VAC circuits in unit mount back pan and DIN rail applications. With patented EverLink lugs on both termination ends to reduce cable loosening over time, a 25kAIC interrupt rating at 600Y\/347VAC (and up to 100kAIC at 240VAC), and an 80% continuous current rating, it supports commercial and industrial distribution applications requiring high fault current protection in a compact single-pole footprint.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":52858781499681,"sku":"BJL16020","price":160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0856\/7763\/7921\/files\/IMG_0001_8292b7d3-52c9-4752-a957-afc7649dd765.jpg?v=1781641156","url":"https:\/\/www.resllcstore.com\/products\/square-d-powerpact-b-bjl16020-20a-1p-600y-347vac-25ka-unit-mount-thermal-magnetic-circuit-breaker","provider":"RES LLC Store","version":"1.0","type":"link"}