{"product_id":"square-d-powerpact-q-qgp22150tm-150a-2p-240vac-65ka-unit-mount-thermal-magnetic-circuit-breaker","title":"Square D PowerPacT Q, QGP22150TM, 150A, 2P, 240VAC, 65kA, Unit Mount, Thermal Magnetic, Circuit Breaker","description":"\u003ch4 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\"\u003eSquare D QGP22150TM: 150 Amp, 2-Pole, PowerPacT Q-Frame Molded Case Circuit Breaker, 240VAC, 65kA, Unit Mount, Thermal Magnetic, 80%, UL Listed.\u003c\/h4\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Square D\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eProduct Range:\u003c\/strong\u003e PowerPacT Q-Frame (for EZ Meter-Pak meter centers and unit mount panel applications)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 785901689959\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e QGP22150TM\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eBreaker Type:\u003c\/strong\u003e Thermal Magnetic Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eMagnetic Tripping Current:\u003c\/strong\u003e 2400A\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eMagnetic Hold Current:\u003c\/strong\u003e 1200A\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 150 Amps\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eContinuous Current Rating:\u003c\/strong\u003e 80%\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 2-Pole\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 240 Volts AC\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eInterrupt Rating:\u003c\/strong\u003e 65 kAIC @ 120\/208VAC and 240VAC\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eBreaking Capacity Code:\u003c\/strong\u003e G\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eMounting Mode:\u003c\/strong\u003e Unit mount (lug) — bottom of panel\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eConnections \/ Terminals:\u003c\/strong\u003e Terminal nut with studs, nuts, and washers (line side); Lugs (load side)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eWire Size:\u003c\/strong\u003e #4 AWG–300 kcmil Cu\/Al\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 247.8 lb-in (#4–300 kcmil)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Height: 6.47 in; Width: 3.00 in; Depth: 3.93 in\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 40°C to 70°C\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e UL 489, CSA, NOM, IEC, HACR Rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThis Square D QGP22150TM PowerPacT Q-Frame thermal magnetic molded case circuit breaker delivers dependable 150 Amp, 2-Pole protection for 240VAC circuits in EZ Meter-Pak meter centers and unit mount panel applications. With a 65kAIC interrupt rating, stud-style line terminals, and an 80% continuous current rating, it supports commercial and multi-family metering distribution applications.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":52858797261089,"sku":"QGP22150TM","price":275.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0856\/7763\/7921\/files\/IMG_0001_3adec0e6-49a1-41a2-87f1-b9958c82d588.jpg?v=1781641579","url":"https:\/\/www.resllcstore.com\/products\/square-d-powerpact-q-qgp22150tm-150a-2p-240vac-65ka-unit-mount-thermal-magnetic-circuit-breaker","provider":"RES LLC Store","version":"1.0","type":"link"}